{"id":3387,"date":"2026-07-07T07:38:02","date_gmt":"2026-07-07T07:38:02","guid":{"rendered":"https:\/\/theemcnews.co.uk\/?page_id=3387"},"modified":"2026-07-07T07:39:38","modified_gmt":"2026-07-07T07:39:38","slug":"ets-lindgren-partners-with-multitel-to-enhance-emc-testing-capabilities","status":"publish","type":"page","link":"https:\/\/theemcnews.co.uk\/index.php\/ets-lindgren-partners-with-multitel-to-enhance-emc-testing-capabilities\/","title":{"rendered":"ETS-Lindgren Partners with Multitel to Enhance EMC Testing Capabilities"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"3387\" class=\"elementor elementor-3387\">\n\t\t\t\t<div class=\"elementor-element elementor-element-87427c2 e-flex e-con-boxed e-con e-parent\" data-id=\"87427c2\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d30e8fa elementor-widget elementor-widget-image\" data-id=\"d30e8fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"300\" height=\"225\" src=\"https:\/\/theemcnews.co.uk\/wp-content\/uploads\/2026\/07\/8000-009-1-300x225-1.jpg\" class=\"attachment-large size-large wp-image-3389\" alt=\"\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-47ab9e0 e-flex e-con-boxed e-con e-parent\" data-id=\"47ab9e0\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d8eba10 elementor-widget elementor-widget-text-editor\" data-id=\"d8eba10\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><b>Cedar Park<\/b>,<b>\u00a0Texas<\/b>,<b>\u00a0<\/b>March 28, 2025 \u2013 ETS\u2011Lindgren, the global leader in Electromagnetic Compatibility (EMC) and Wireless Testing Solutions, has partnered with Multitel, a commercial EMC test lab based in Mons, Belgium, to create a state-of-the-art 3-meter EMC chamber customized to meet the lab\u2019s specific testing needs. This collaboration underscores ETS\u2011Lindgren\u2019s commitment to providing reliable, innovative solutions for complex testing challenges.<\/p><p>The chamber, a\u00a0<a href=\"https:\/\/www.ets-lindgren.com\/products\/chambers\/fact-chambers\/5004\/500405?page=Products-Item-Page\">FACT\u2122 3<\/a>\u00a0(Free-Space Anechoic Chamber Test-Site), is a modular RF-shielded enclosure designed to maximize space efficiency without compromising functionality. With internal shield dimensions of 8.48 m L x 5.12 m W x 5.84 m H (28 ft x 17 ft x 19 ft), the chamber creates a controlled, high-performance testing environment for a variety of applications.<\/p><p>At the heart of the FACT\u2122 3 chamber is ETS\u2011Lindgren\u2019s\u00a0<a href=\"https:\/\/www.ets-lindgren.com\/products\/absorbers\/polystyrene-hybrid-absorber\/1005\/100503?page=Products-Item-Page\">DuraSorb\u2122 DSH-400H<\/a>\u00a0Absorber. This technology combines the performance of FerroSorb\u2122 with the durability of PS Series absorbers, providing a reflectivity of better than -15 dB from 80 MHz to 300 MHz and better than -20 dB above 300 MHz, ensuring consistency from low to high frequencies.<\/p><p>The modular RF-shielded control room complements the chamber\u2019s design. Constructed from 2-mm galvanized steel panels, the control room measures 4 m L x 2.56 m W x 2.48 m H (13 ft x 8.3 ft x 8 ft). The integration of the control room with the semi-anechoic chamber ensures seamless operation and optimum space usage.<\/p><p>\u201cThis project is particularly meaningful to us because it highlights our ability to solve complex challenges with dependable solutions,\u201d said Janet O\u2019Neil, Customer Relationship Manager at ETS\u2011Lindgren. \u201cBy collaborating with Multitel, we\u2019ve delivered a chamber that meets the highest standards for EMC testing, providing them with the precision and flexibility needed in today\u2019s rapidly advancing technological landscape.\u201d<\/p><p>The chamber underwent comprehensive verification processes to ensure its superior shielding and absorber performance, solidifying its role as an essential tool for testing in both commercial and industrial applications.<\/p><p>Through this partnership, ETS\u2011Lindgren reaffirmed its dedication to offering not only advanced technological solutions but also tailored, customer-focused service. By working closely with Multitel, ETS\u2011Lindgren has demonstrated its ability to meet the evolving needs of the EMC testing community, setting a new benchmark for the industry.<\/p><p>To learn more about the case study and the project, visit the full details on the\u00a0<a href=\"https:\/\/www.ets-lindgren.com\/downloads\/ProjectProfiles\/Multitel_Case_Study_rev_1.0.pdf\">ETS\u2011Lindgren website<\/a>.<\/p><p><b>About ETS\u2011Lindgren<\/b><\/p><p>ETS\u2011Lindgren is an international manufacturer of components and systems that measure, shield, and control electromagnetic and acoustic energy. The company\u2019s products are used for electromagnetic compatibility (EMC), microwave, wireless, and magnetic resonance imaging (MRI) testing, electromagnetic field (EMF) measurement, radio frequency (RF) personal safety monitoring, and control of acoustic environments.<\/p><p>Headquartered in Cedar Park, Texas, ETS\u2011Lindgren has manufacturing facilities in North America, Europe, and Asia. The company is a wholly owned subsidiary of ESCO Technologies, a leading supplier of engineered products for growing industrial and commercial markets. ESCO is a New York Stock Exchange listed company (symbol ESE) with headquarters in St. Louis, Missouri. Additional information about ETS\u2011Lindgren is available at<a href=\"https:\/\/www.ets-lindgren.com\/\" target=\"_blank\" rel=\"noopener\"><b>www.ets-lindgren.com<\/b><\/a>. Follow ETS\u2011Lindgren on<a href=\"https:\/\/www.facebook.com\/ETSLindgren\/\" target=\"_blank\" rel=\"noopener\"><b>Facebook<\/b><\/a>,<u><\/u><a href=\"https:\/\/www.instagram.com\/ets.lindgren\/\" target=\"_blank\" rel=\"noopener\"><b>Instagram<\/b><\/a>,<a href=\"https:\/\/www.linkedin.com\/company\/ets-lindgren\/\" target=\"_blank\" rel=\"noopener\"><b>LinkedIn<\/b><\/a>,<a href=\"https:\/\/twitter.com\/ETSLindgren\" target=\"_blank\" rel=\"noopener\"><b>X<\/b><\/a>, and<a href=\"https:\/\/www.youtube.com\/user\/etslindgrenvideo\" target=\"_blank\" rel=\"noopener\"><b>YouTube<\/b><\/a>. Additional information about ESCO and its subsidiaries is available at<a href=\"https:\/\/www.escotechnologies.com\/\" target=\"_blank\" rel=\"noopener\"><b>www.escotechnologies.com<\/b><\/a>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Cedar Park,\u00a0Texas,\u00a0March 28, 2025 \u2013 ETS\u2011Lindgren, the global leader in Electromagnetic Compatibility (EMC) and Wireless Testing Solutions, has partnered with Multitel, a commercial EMC test lab based in Mons, Belgium, to create a state-of-the-art 3-meter EMC chamber customized to meet the lab\u2019s specific testing needs. This collaboration underscores ETS\u2011Lindgren\u2019s commitment&hellip; <\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-3387","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/theemcnews.co.uk\/index.php\/wp-json\/wp\/v2\/pages\/3387","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/theemcnews.co.uk\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/theemcnews.co.uk\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/theemcnews.co.uk\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/theemcnews.co.uk\/index.php\/wp-json\/wp\/v2\/comments?post=3387"}],"version-history":[{"count":4,"href":"https:\/\/theemcnews.co.uk\/index.php\/wp-json\/wp\/v2\/pages\/3387\/revisions"}],"predecessor-version":[{"id":3401,"href":"https:\/\/theemcnews.co.uk\/index.php\/wp-json\/wp\/v2\/pages\/3387\/revisions\/3401"}],"wp:attachment":[{"href":"https:\/\/theemcnews.co.uk\/index.php\/wp-json\/wp\/v2\/media?parent=3387"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}